0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HX 05-NP

HX 05-NP

  • 厂商:

    LEM(莱姆)

  • 封装:

  • 描述:

    LEM - HX 05-NP - Current Transducer, HX Series, PCB, 5A, -15A to 15A, 1 %, Voltage Output, 15 Vdc

  • 数据手册
  • 价格&库存
HX 05-NP 数据手册
Current Transducer HX 05 .. 15-NP IPN = 5 .. 15 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary nominal current rms IPN (A) Primary current, measuring range IPM (A) Serial Series Parallel ±5 ± 10 ± 15 ± 10 ± 20 ± 30 VOUT ROUT RL VC IC Vd ± 15 ± 30 ± 45 Primary conductor diameter x turns (mm) Type • Galvanic isolation between primary ± 30 ± 60 ± 90 0.8d x (6T+6T) 1.0d x (3T+3T) 1.2d x (2T+2T) HX 05-NP HX 10-NP HX 15-NP planned planned 46047 ±4 < 50 ≥ 10 ± 15 < ± 15 >3 >1 ≥1 ≥6 V Ω kΩ V mA kV kV kV kV ε L VOE VOH TCVOE TCVOUT tr BW Accuracy @ IPN, TA = 25°C (excluding offset) Linearity error (0 .. ± IPN) Electrical offset voltage @ TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Temperature coefficient of VOE Temperature coefficient of VOE (% of reading) Response time to 90% of IPN step Frequency bandwidth (- 3 dB) 2) Ambient operating temperature Ambient storage temperature Mass Creepage distance Isolation material group Standards and secondary circuit Hall effect measuring principle Isolation voltage 3000V 2 isolated primary windings Low power consumption Extended measuring range(3 x IPN) Power supply from ±12V to ±15V Isolated plastic case recognized according to UL94-V0. Advantages • Low insertion losses • Easy to mount with automatic handling system ratings range < ± 1 % of IPN < ± 1 % of IPN < ± 40 mV < ± 15 < ± 1.5 ± 0.1 ≤3 50 mV mV/K %/K µs kHz General data TA TS m dCp • • • • • • • • Only one design for wide current Accuracy-Dynamic performance data X Features Parallel Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance Load resistance Supply voltage (± 5 %)1) Current consumption Rms voltage for AC isolation test, 50 Hz, 1 min Primary to secondary Primary 1 to primary 2 Partial discharge extinction voltage rms @ 10 pC Impulse withstand voltage, 1.2/50 µs Ve VW RoHS since date code • Small size and space saving • High immunity to external interference. Applications • Switched Mode Power Supplies (SMPS) • AC variable speed drives • Uninterruptible Power Supplies (UPS) - 25 .. + 85 °C - 25 .. + 85 °C 8 g ≥ 5.5 mm I EN50178: 1997 • Electrical appliances • Battery supplied applications • DC motor drives Application domain • Industrial 1) Notes : Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN 2) Small signal only to avoid excessive heating of the magnetic core Page 1/2 071029/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HX 05..15-NP (in mm. 1 mm = 0.0394 inch) 15.4 Max. 0.5 20 Max. 19 Max. d 4 3.5+/-0.5 10.85 OUT 3 +V 0 2 8 7 5 HX 05-NP 41123 3.5 1 -V or 0 Top view 6 6 4 4.5 P=2.54 6 3 10.85 4 Lot No. Terminal Pin Identification 1...... -15V 2...... 0V 3...... +15V 4...... Output 5...... Primary 1 input Current(-) 7...... Primary 1 input Current(+) 6...... Primary 2 input Current(-) 8...... Primary 2 input Current(+) Mechanical characteristics • General tolerance Primary conductor diameter HX HX 05-NP 05-NP10-NP 10-NP dd 0.8 0.8 1.0 1.0 15-NP 1.2 Secondary pins dimension 0.5 x 0.25 Safety ± 0.5 mm This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 071029/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
HX 05-NP 价格&库存

很抱歉,暂时无法提供与“HX 05-NP”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HX 05-NP
  •  国内价格
  • 1+279.31397
  • 15+273.77301
  • 25+269.00328

库存:138

HX 05-NP
  •  国内价格
  • 1+240.34095
  • 15+235.57141
  • 25+231.46836

库存:27